Model Inputs
{'MODEL_DIR': '/Users/dpinney/gdrive/LATERBASE/NRECA/MICROGRIDUP (MGU) ESTCP FY2020/del2.2.1K - Requirements and Specifications/microgridup mgu test system lehigh/data/projects/auto3mg', 'BASE_DSS': '/Users/dpinney/gdrive/LATERBASE/NRECA/MICROGRIDUP (MGU) ESTCP FY2020/del2.2.1K - Requirements and Specifications/microgridup mgu test system lehigh/testfiles/lehigh_base_3mg.dss', 'LOAD_CSV': '/Users/dpinney/gdrive/LATERBASE/NRECA/MICROGRIDUP (MGU) ESTCP FY2020/del2.2.1K - Requirements and Specifications/microgridup mgu test system lehigh/testfiles/lehigh_load.csv', 'QSTS_STEPS': 480, 'FOSSIL_BACKUP_PERCENT': 0.5, 'REOPT_INPUTS': {'solar': 'on', 'wind': 'off', 'battery': 'on', 'year': '2017', 'analysisYears': '25', 'discountRate': '0.083', 'energyCost': '0.12', 'demandCost': '20', 'urdbLabelSwitch': 'off', 'wholesaleCost': '0', 'solarCost': '1600', 'windCost': '4989', 'batteryPowerCost': '840', 'batteryCapacityCost': '420', 'batteryPowerCostReplace': '410', 'batteryCapacityCostReplace': '200', 'batteryPowerReplaceYear': '10', 'batteryCapacityReplaceYear': '10', 'dieselGenCost': '1000', 'solarMin': 0, 'windMin': 0, 'batteryPowerMin': 0, 'batteryCapacityMin': 0, 'solarMax': '100000', 'windMax': '100000', 'batteryPowerMax': '100000', 'batteryCapacityMax': '100000', 'dieselMax': '100000', 'solarExisting': 0, 'criticalLoadFactor': '1', 'outageDuration': '48', 'fuelAvailable': '10000', 'genExisting': 0, 'minGenLoading': '0.3', 'batteryKwExisting': 0, 'batteryKwhExisting': 0, 'windExisting': 0, 'dieselFuelCostGal': 3, 'dieselCO2Factor': 22.4, 'dieselOMCostKw': 25, 'dieselOMCostKwh': 0.02, 'value_of_lost_load': '100', 'solarCanCurtail': True, 'solarCanExport': True, 'dieselOnlyRunsDuringOutage': True}, 'MICROGRIDS': {'mg0': {'loads': ['634a_data_center', '634b_radar', '634c_atc_tower'], 'switch': ['632633'], 'gen_bus': '633', 'gen_obs_existing': ['solar_634_existing'], 'critical_load_kws': [160.0, 120.0, 120.0], 'max_potential': '700', 'max_potential_diesel': '1000000', 'battery_capacity': '10000'}, 'mg1': {'loads': ['645_hangar', '646_office'], 'switch': ['632645'], 'gen_bus': '645', 'gen_obs_existing': [], 'critical_load_kws': [170.0, 0.0], 'max_potential': '700', 'max_potential_diesel': '1000000', 'battery_capacity': '10000'}, 'mg2': {'loads': ['684_command_center', '692_warehouse2', '675a_hospital', '675b_residential1', '675c_residential1', '611_runway', '652_residential', '670a_residential2', '670b_residential2', '670c_residential2'], 'switch': ['632670'], 'gen_bus': '670', 'gen_obs_existing': ['fossil_675_existing'], 'critical_load_kws': [1155.0, 0.0, 485.0, 0.0, 0.0, 170.0, 0.0, 0.0, 0.0, 0.0], 'max_potential': '700', 'max_potential_diesel': '1000000', 'battery_capacity': '10000'}}, 'FAULTED_LINE': '670671', 'DIESEL_SAFETY_FACTOR': False, 'OUTAGE_CSV': '/Users/dpinney/gdrive/LATERBASE/NRECA/MICROGRIDUP (MGU) ESTCP FY2020/del2.2.1K - Requirements and Specifications/microgridup mgu test system lehigh/testfiles/lehigh_random_outages.csv'}